<?xml version="1.0" encoding="utf-16"?><rss xmlns:a10="http://www.w3.org/2005/Atom" version="2.0"><channel><title>Danfoss Drives</title><link>http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTMicroDrive/ProductBrochure/RSS.ashx</link><description>Danfoss Drives Pages</description><lastBuildDate>Thu, 27 Nov 2008 13:31:58 +0100</lastBuildDate><a10:id>http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTMicroDrive/ProductBrochure/</a10:id><item><guid isPermaLink="true">http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTMicroDrive/ProductBrochure/?Page=1</guid><link>http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTMicroDrive/ProductBrochure/?Page=1</link><title>Danfoss Drives Page 1</title><description>VLT&amp;#174; Micro Drive Small drive – maximum strength and reliability 1</description><a10:updated>2008-11-27T13:31:58+01:00</a10:updated></item><item><guid isPermaLink="true">http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTMicroDrive/ProductBrochure/?Page=2</guid><link>http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTMicroDrive/ProductBrochure/?Page=2</link><title>Danfoss Drives Page 2</title><description>Well protected IP 20 enclosure No forced air flow through electronics Hot pluggable LCP High quality capacitors RFI Filter LCD display RS 485 pluggable Customer relay screw terminals Wire inlet from the bottom DC-link access I/O terminals Potentiometer Mains screw terminals Safety earth – min. 4 mm2 accessible from front IP 20 even without terminal cover Motor screw terminals Ready – Steady – Go! Connect motor and power cables, turn the control knob, and watch the motor speed change. RoHS compliant The VLT&amp;#174; Micro Drive does not contain lead, cadmium, hexavalent chrome, mercury, or flame retardant PBB and PBDE. 2</description><a10:updated>2008-11-27T13:31:58+01:00</a10:updated></item><item><guid isPermaLink="true">http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTMicroDrive/ProductBrochure/?Page=3</guid><link>http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTMicroDrive/ProductBrochure/?Page=3</link><title>Danfoss Drives Page 3</title><description>Compact VLT&amp;#174; quality VLT&amp;#174; Micro Drive is a genuine VLT&amp;#174; frequency converter with unsurpassed reliability, user-friendliness, condensed functionality, and extremely easy to commission. Terminal numbers are named in the same manner as in the rest of the VLT&amp;#174; family. It’s developed and manufactured by Danfoss Drives, the leading drives experts since 1968 and creators of VLT&amp;#174; – The Real Drive. User friendly VLT&amp;#174; Micro Drive shares the user-friendliness of the VLT&amp;#174; family. • Plug-and-play • Minimum commissioning • Copy settings via local control panel • Intuitive parameter structure • Complies with VLT&amp;#174; software – Minimum effort – minimum time – Save time – Easy set up of multiple drives – Minimal manual reading – Save commissioning time Reliable VLT&amp;#174; Micro Drive is a full member of the VLT&amp;#174; family sharing the overall quality of design, reliability and user-friendliness. High quality components and genuine VLT&amp;#174; solutions makes VLT&amp;#174; Micro Drive extremely reliable. • Optimum heat dissipation • High quality electronics/capasitors • All drives full load tested from factory • Earth fault, temperature and short circuit protection • Circuit boards well protected and coated – Longer lifetime – Low lifetime cost – High reliability – Lean operation – Increased robustness In- and outputs • 5 programmable Digital inputs • PNP/NPN selection • Pulse input 20 – 5000 Hz • 1 Analogue input 0 – 10 V or 0 – 20 mA • 1 analogue input 0 – 20 mA • Thermistor input (analogue/digital) • 1 Analogue output 0 – 20 mA • 1 Relay 240 V AC, 2 A • RS485 FC-bus • Modbus RTU Compact general purpose drive The VLT&amp;#174; Micro Drive is a general purpose drive that can control AC motors up to 7.5 kW. Small drive – high performance Despite the compact size and the easy commissioning, VLT&amp;#174; Micro Drive can be set up to perform perfectly even in complex application set-ups. Approximately 100 parameters can be set to optimize energy efficiency and operation. • Process PI-controller • Automatic Energy Optimizer (AEO) • Automatic Motor Tuning (AMT) • 150% motor torque up to 1 minute • Flying start (catch a spinning motor) • Electronic Thermal relay (ETR) • Smart Logic Controller • Built-in RFI filter – No need for external controller – Less energy consumption – Exploit motor’s full potential – Replace need for bigger drive – Lean operation – more up-time – Replace external motor protection – Often makes PLC ommissible – Save cost and space 3</description><a10:updated>2008-11-27T13:31:58+01:00</a10:updated></item><item><guid isPermaLink="true">http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTMicroDrive/ProductBrochure/?Page=4</guid><link>http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTMicroDrive/ProductBrochure/?Page=4</link><title>Danfoss Drives Page 4</title><description>Compact design Uncompromised quality Ensured reliability and maximum up/time Real space saving side-by-side A compact book style design allows real side by side mounting without derating. Minimum penetration of dust VLT&amp;#174; Micro Drive is designed to keep the forced ventilation away from the electronics. Printed circuit boards are well protected inside the drive. Built-in RFI Radio disturbance from motor cables is limited with the built-in RFI filter allowing for 15 m motor cables (screened). Meets EU norms. Built-in brake functions With built in DC and AC brake functions, VLT&amp;#174; Micro Drive can transform kinetic energy in the application into braking power to slow down the motor. A brake chopper is built-in the drives from 1.5 kW upwards. Designed for reliability in industrial applications Intelligent heat management Process heat is removed through the heat sink, leaving electronics protected from dust and dirt from production. Effective heat sink An effective heat sink easily removes heat from the electronics, extending lifetime and reliability of the drive. Coated electronics are standard All VLT&amp;#174; Micro Drive comes with coated electronics for longer lifetime and reliability. Energy efficiency 98% High quality VLT&amp;#174; power modules ensure cool running of the drive due to low losses. 50˚ ambient temperature Highly efficient cooling allows up to 50˚ ambient temperature. 4</description><a10:updated>2008-11-27T13:31:58+01:00</a10:updated></item><item><guid isPermaLink="true">http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTMicroDrive/ProductBrochure/?Page=5</guid><link>http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTMicroDrive/ProductBrochure/?Page=5</link><title>Danfoss Drives Page 5</title><description>Hot pluggable display – with or without potentiometer • • • • • • • • • • LCP without potentiometer IP 54 LCP with potentiometer IP 21 Remote mounting kit LCP copy function Parameter numbers and values visible simultaneously Unit indications (A., V, Hz, RPM, %, s, HP and kW) Rotation direction indication Setup indication – 2 setup Removable during operation Up- and download functionality Remote mountable Illuminated LCD display Navigation buttons Large figures, easy to read • Display readable from distance • Operation buttons are illuminated when active Quick Menus • A Danfoss defined Quick Menu • Basic settings • PI controller Menu structure • Based on the well-known matrix from the VLT&amp;#174; family • Easy shortcut for the experienced user • Edit and operate in different set-ups simultaneously Indicators Operation buttons Two control panel versions. Potentiometer is optional. The control panels are shown in actual size. H x W x D = 85 x 65 x 20 mm (D = 28 mm w. potmeter) Built-in Smart Logic Controller The smart logic controller is a simple, and yet very clever way to have your drive, motor and application working together. The smart logic controller is able to monitor any parameter that can be characterized as “true” or “false”. This includes digital commands and also logic expressions, which allows even sensor outputs to influence the operation. Temperature, pressure, flow, time, load, frequency, voltage and other parameters combined with the operators “&amp;gt;”, “&amp;lt;”, “=”, “and” and “or” forms logic expressions that are false or true. That is why Danfoss calls it a “logic” controller. As a result of this, you can program the controller to react on literally any event. 5</description><a10:updated>2008-11-27T13:31:58+01:00</a10:updated></item><item><guid isPermaLink="true">http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTMicroDrive/ProductBrochure/?Page=6</guid><link>http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTMicroDrive/ProductBrochure/?Page=6</link><title>Danfoss Drives Page 6</title><description>Connections Factory settings Accessories Code numbers VLT&amp;#174; Control panel LCP 11 W/o potentiometer . 132B0100 VLT&amp;#174; Control panel LCP 12 With potentiometer. 132B0101 Remote mounting kit incl. 3 m cable . 132B0102 Set-up software The VLT&amp;#174; Motion Control Tool MCT 10 Setup Software exploits the full functionality of your PC, providing a general overview and control of even large systems. 6 Remote mounting kit A dedicated mounting kit is available for mounting the local control panel (LCP) in the cabinet door. Decoupling plate For EMC optimized installation. Dedicated external filters are available on request.</description><a10:updated>2008-11-27T13:31:58+01:00</a10:updated></item><item><guid isPermaLink="true">http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTMicroDrive/ProductBrochure/?Page=7</guid><link>http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTMicroDrive/ProductBrochure/?Page=7</link><title>Danfoss Drives Page 7</title><description>Specifications Mains supply (L1, L2, L3) Supply voltage Supply voltage Supply voltage Output data (U, V, W) Output voltage Output frequency Output frequency Switching on output Ramp times Digital inputs Programmable inputs Logic Voltage level Maximum voltage on input Input Resistance, Ri Pulse inputs Programmable pulse inputs Voltage level Pulse input accuracy (0,1–110 kHz) Pulse input frequency Analog input Analog inputs Modes Voltage level Current level Analog output Programmable analog outputs Current range at analog output Max. load to common at analog output Accuracy on analog output 1 0/4–20 mA 500 Ω Max. error: 1% of full scale 2 1 current/1 voltage or current 0 – 10 V (scaleable) 0/4 – (scaleable) 1 0 – 24 V DC (PNP positive logic) Max. error: 0.1% of full scale 20 – 5000 Hz 5 PNP or NPN 0 – 24 V 28 V DC Approx. 4 kΩ 0 – 100% of supply voltage 0 – 200 Hz (VVC+ mode) 0 – 400 Hz (U/f mode) Unlimited 0.05 – 3600 sec 1 x 200 – 240 V &amp;#177; 10% 3 x 200 – 240 V &amp;#177; 10% 3 x 380 – 480 V &amp;#177; 10% On-board power supply Output voltage Max. load (10 V) Max. load (24 V) Relay outputs Programmable relay outputs Max. terminal load Cable lengths Max. motor cable length, screened (shielded) Max. motor cable length, unscreened (unshielded) Surroundings/ External Enclosure Vibration test Max. relative humidity Aggressive environment Ambient temperature 24-hour average Protection and features • Electronic thermal motor protection against overload • Temperature monitoring of the heat sink protects the drive from overheating • The drive is protected against short-circuits on motor terminals U, V, W • The drive is protected against earth fault on motor terminals U, V, W IP 20 0.7 g 5% – 95% (IEC 721-3-3; Class 3K3 (non-condensing) during operation (IEC 721-3-3), coated class 3C3 Max. 50&amp;#176; C Max. 40&amp;#176; C 15 m 50 m 1 240 V AC, 2 A 10.5 &amp;#177; 0.5 V 15 mA 130 mA Ordering numbers 200 V Power [kW] 0.18 0.25 0.37 0.75 1.5 2.2 3.0 3.7 4.0 5.5 7.5 Current [I-nom.] 1.2 1.5 2.2 4.2 6.8 9.6 15.2 1 ph. 132F 0001 132F 0002 132F 0003 132F 0005 132F 0007 132F 0008 132F 0009 132F 0010 132F 0012 132F 0014 132F 0016 9 12 15.5 132F 0026 132F 0028 132F 0030 1.2 2.2 3.7 5.3 7.2 132F 0017 132F 0018 132F 0020 132F 0022 132F 0024 3 ph. Current [I-nom.] 400 V 3 ph. M1 M2 M3 Cabinet sizes (mounting brackets incl.) [mm] Height Width Depth + 6 mm with potentiometer Micro drives from 1.5 kW and up have built in brake chopper M1 150 70 148 M2 180 75 168 M3 239 90 194 7</description><a10:updated>2008-11-27T13:31:58+01:00</a10:updated></item><item><guid isPermaLink="true">http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTMicroDrive/ProductBrochure/?Page=8</guid><link>http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTMicroDrive/ProductBrochure/?Page=8</link><title>Danfoss Drives Page 8</title><description>What VLT&amp;#174; is all about Danfoss Drives is the world leader among dedicated drives providers – and still gaining market share. Dedicated to drives Dedication has been a key word since 1968, when Danfoss introduced the world’s first mass produced variable speed drive for AC motors – and named it VLT&amp;#174;. Two thousand employees develop, manufacture, sell and service drives and softstarters in more than one hundred countries, focused only on drives and softstarters. Intelligent and innovative Developers at Danfoss Drives have fully adopted modular principles in development as well as design, production and configuration. Tomorrow’s features are developed in parallel using dedicated technology platforms. This allows the development of all elements to take place in parallel, at the same time reducing time to market and ensuring that customers always enjoy the benefits of the latest features. Rely on the experts We take responsibility for every element in our products. The fact that we develop and produce our own features, hardware, software, power modules, printed circuit boards, and accessories is your guarantee for reliable products. Local backup – globally VLT&amp;#174; motor controllers are operating in applications all over the world and Danfoss Drives’ experts located in more than 100 countries are ready to support our customers with application advice and service wherever they may be. Danfoss Drives experts don’t stop until the customer’s drive challenges are solved. Protects environment VLT&amp;#174; products are manufactured with respect for environment, safety and wellbeing. All activities are planned and performed taking into account the individual employee, the work environment and the external environment. Production takes place with a minimum of noise, smoke or other pollution and environmentally safe disposal of the products is assured. UN Global Compact Danfoss has signed the UN Global Compact on social and environmental responsibility and our companies act responsibly towards local societies. EU Directives All factories are certiﬁed according to ISO 14001 standard. All products fulﬁl the EU Directives for General Product Safety and the Machinery directive. Danfoss Drives is in all product series implementing the EU Directive concerning Hazardous Substances in Electrical and Electrical Equipment (RoHS) and is designing all new product series according to the EU Directive on Waste Electrical and Electronic Equipment (WEEE). Products impact One year’s production of VLT&amp;#174; drives will save energy equivalent to the energy production of a power plant. Better process control at the same time improves product quality and reduces waste and wear on equipment. Danfoss Drives, Ulsnaes 1, DK-6300 Graasten, Denmark, Tel. +45 74 88 22 22, Fax +45 74 65 25 80, www.danfoss.com/drives • E-mail: info@danfoss.com DKDD.PB.18.A1.02 VLT&amp;#174; is a trademark of Danfoss A/S Produced by KKM 2007.09</description><a10:updated>2008-11-27T13:31:58+01:00</a10:updated></item></channel></rss>