<?xml version="1.0" encoding="utf-16"?><rss xmlns:a10="http://www.w3.org/2005/Atom" version="2.0"><channel><title>Danfoss Drives</title><link>http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/RSS.ashx</link><description>Danfoss Drives Pages</description><lastBuildDate>Thu, 27 Nov 2008 13:08:03 +0100</lastBuildDate><a10:id>http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/</a10:id><item><guid isPermaLink="true">http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=1</guid><link>http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=1</link><title>Danfoss Drives Page 1</title><description>MAKING MODERN LIVING POSSIBLE VLT&amp;#174; AQUA Drive The ultimate solution for Water, Wastewater &amp;amp; Irrigation</description><a10:updated>2008-11-27T13:08:03+01:00</a10:updated></item><item><guid isPermaLink="true">http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=2</guid><link>http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=2</link><title>Danfoss Drives Page 2</title><description>Dedicated to pumps and blowers Higher water quality and significant energy savings can be achieved in any water system with the VLT&amp;#174; AQUA Drive. Water supply, water treatment, water distribution, pressure control, level control, wastewater treatment, irrigation – you name the need, we name the solution – the VLT&amp;#174; AQUA Drive. 2</description><a10:updated>2008-11-27T13:08:03+01:00</a10:updated></item><item><guid isPermaLink="true">http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=3</guid><link>http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=3</link><title>Danfoss Drives Page 3</title><description>The VLT&amp;#174; AQUA Drive is intelligent – makes water management simple Danfoss VLT&amp;#174; AQUA Drive is dedicated to water and wastewater applications. With a wide range of powerful standard and optional features, the VLT&amp;#174; AQUA Drive provides the lowest overall cost of ownership for water and wastewater applications. Save energy The VLT&amp;#174; AQUA Drive oﬀers considerable energy savings: • VLT&amp;#174; eﬃciency (up to 98%) • Sleep Mode • Automatic Energy Optimisation AEO: Typically 3-5% – up to 15% not unusual • Flow compensation, lowering pressure set point and thus energy consumption under low ﬂow conditions. Save space The compact design of the VLT&amp;#174; AQUA Drive makes it easily ﬁt in even small installation spaces. • Built-in DC coils for harmonic suppression. No need for external AC coils • Optional, built-in RFI ﬁlters in the whole power range • Intelligent cooling concept reduces need for installation space. Save cost and protect your system with a series of pump-speciﬁc features: • • • • • • • • • • • • • • • Cascade controller Dry run detection End of curve detection Motor alternation 2-step ramps (initial and ﬁnal ramp) Check valve protection Safe stop Low ﬂow detection Pipe ﬁll mode Sleep mode Real-time clock Password protection Overload trip protection Smart logic controller Cavitation protection Save time VLT&amp;#174; AQUA Drive is designed with the installer and operator in mind in order to save time on installation, commissioning and maintenance. • Intuitive user interface with the award-winning control panel (LCP) • One drive type for the full power range • Modular VLT&amp;#174; design enables fast installation of options • Auto tuning of PI controllers • Robust design and eﬃcient monitoring make the VLT&amp;#174; AQUA Drive maintenance free. Dedicated to water and wastewater Danfoss Drives’ unequalled experience was used to make the VLT&amp;#174; AQUA Drive the perfect match for AC motor driven applications in modern water and wastewater systems. Water and Wastewater is a global business area for Danfoss Drives and you will ﬁnd our dedicated sales and service staﬀ all over the world 24 hours a day. Can be set to either variable or constant torque operation in the full speed range. Save cabinet NEMA/UL Type 12 (IP 54/55) enclosure solution is available in the whole power range. Up to 90 kW, the VLT&amp;#174; AQUA Drive can even be delivered in an IP 66 version. Energy savings using a VLT&amp;#174; AQUA Drive are achieved even with a modest reduction in speed. Reducing water losses by lowering system pressure becomes increasingly eﬀective as the size of line breaks increase. 3</description><a10:updated>2008-11-27T13:08:03+01:00</a10:updated></item><item><guid isPermaLink="true">http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=4</guid><link>http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=4</link><title>Danfoss Drives Page 4</title><description>The modular VLT&amp;#174; AQUA Drive Extremely compact panel mount cabinets Mains and motor cable terminals are located in the bottom of the cabinet for fast and easy installation. ➊ Fieldbus option – Modbus RTU (std.) – Proﬁbus – Devicenet – Ethernet (Proﬁnet to come) ➋ Local Control Panel (LCP) Choose numerical, graphical or no display ➌ I/O option – General Purpose I/O (3DI + 2AI + 2DO + 1AO) – Cascade controller (6 or 8 pumps) – Sensor input (3 x PT100/1000 + 1AI) – Relay output (3 x relays) ➍ 24 V supply option ➎ RFI ﬁlter Built-in RFI Filter for long motor cables according to the IEC 61800-3 and EN 55011 standards. ➏ AC mains disconnect (Factory mounted option) ➐ Input mains option Various input plate conﬁgurations are available including fuses, mains switch (disconnect), or RFI ﬁlter. Input plates are ﬁeld adaptable if options need to be added after installation. C3 – frame IP 20 compact panel mounting drive. The IP 20 enclosure has two individually controlled fans for maximum reliability. Only a minimum of cooling air passes the electronic components, which increases the lifetime. The aluminium front hinged door ensures easy access to additional I/O options and control wiring. IP 21/Type 1 protection can be delivered as a kit solution or as a speciﬁc IP 21 drive with easy access plastic cover with snap locks. Extremely robust cabinets for harsh environments The Danfoss IP 55/NEMA 12 or IP 66 are designed for use in harsh environments with gas, pollution and dust. The electronics are completely separated from the cooling air in order to increase the lifetime. All terminals and EMC connections are located inside the drive under the robust metal cover for maximum protection. If ordered as IP 66 the heat sink is protected against corrosion (IP 66 rating is available up to 90 kW). Coated PCB’s ➑ Durable in aggressive environments In water and wastewater applications it is often recommended to protect the drive with coated PCB’s. As standard the VLT&amp;#174; AQUA Drive complies with level 3C2 according to IEC 60721-3-3. Protection level 3C3 is optionally delivered from factory. The option protects signiﬁcantly better against chlorine, hydrogen sulphide, ammonia and other gasses. 4</description><a10:updated>2008-11-27T13:08:03+01:00</a10:updated></item><item><guid isPermaLink="true">http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=5</guid><link>http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=5</link><title>Danfoss Drives Page 5</title><description>➒ ➒ Unique cooling concept – No ambient air ﬂow over electronics up to 90 kW – Above 90 kW designed with back channel cooling (85% heat dissipated via back channel) ➓ Advanced cascade controller option Controls up to 8 pumps ➓ ➊ ➌ ➋ ➑ VLT&amp;#174; quality up to 1.2 MW The VLT&amp;#174; AQUA Drive is available from 0.25 kW to 1.2 MW. Drive experience since 1968 lies behind the clever design of VLT&amp;#174; drives. All enclosures are mechanically designed with focus on: • • • • Robustness Easy access and installation Intelligent cooling High ambient temperatures ➎ ➍ From 0.25 kW to 90 kW the VLT&amp;#174; AQUA Drive is available in IP 20, IP 21/ NEMA 1, IP 55/NEMA 12 and IP 66 enclosure ratings. From 90 kW to 1.2 MW it is available in IP 00, IP 21/NEMA1 and IP 54/NEMA12 enclosure ratings. The broad enclosure protection range makes VLT&amp;#174; AQUA Drive the perfect choice for all water and wastewater applications. All VLT&amp;#174; AQUA Drives share technology, user interface and basic features with the rest of the new VLT&amp;#174; generation to assure well documented and proven quality. The modular design of the VLT&amp;#174; AQUA Drive allows even highly customised drives to be mass produced and factory tested. Plug and play options make upgrading easy and ensure ﬂexibility. ➏ ➐ ➑ DC coils reduce harmonic noise and protect the drive. Also EMC ﬁlters are integrated (meets EN 55011 A2, A1 or B). Remote access via fieldbus and USB cable. VLT&amp;#174; Set up Software MCT 10 gives intuitive access to all parameters and has scope features with graphs showing feedback, current, frequency etc. for easy fault finding and documentation. 5</description><a10:updated>2008-11-27T13:08:03+01:00</a10:updated></item><item><guid isPermaLink="true">http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=6</guid><link>http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=6</link><title>Danfoss Drives Page 6</title><description>Water and Wastewater treatment – Improved process control using less energy Desalination plants Desalination plants are used to provide clean drinking water from the sea. The process uses high pressure pumps, which must be carefully controlled. With its built-in PID controller, the VLT&amp;#174; AQUA Drive ensures reliable and precise pressure control, maximising process control and eﬃciency. Groundwater pumps Submersible deep well pumps need fast start capability, precise control and protection against running dry. The built-in dry run detection and the initial ramp-up make the VLT&amp;#174; AQUA Drive handle such applications to perfection. Wastewater plants Fluctuations in ﬂow can disturb the process and lead to increased costs, increased wear on machines through higher number of starts and stops. Using the VLT&amp;#174; AQUA Drive on pumps, blowers and other equipment will lead to a balanced process and save considerable amounts of energy. The built-in logic can be programmed to prevent segmenting etc. in the pump impellars. 6</description><a10:updated>2008-11-27T13:08:03+01:00</a10:updated></item><item><guid isPermaLink="true">http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=7</guid><link>http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=7</link><title>Danfoss Drives Page 7</title><description>Irrigation systems In irrigation today great concerns are put on eﬃciency and energy savings in the water management. Precise pressure control is required. The built-in pump control makes VLT&amp;#174; AQUA Drive a perfect match for irrigation in rural areas. It even oﬀers a special pipe ﬁll function that prevents water hammering and reduces leakage when empty pipes are ﬁlled. The capability to work in variable and constant torque mode makes VLT&amp;#174; AQUA Drive suitable for all wastewater applications. Distribution Pressure booster pumps with precise pressure control lead to signiﬁcant reductions in water leakage and energy consumption. Costly and unsightly water towers can be eliminated. Built-in features make transducer installation very easy and ensure optimised energy saving at varying ﬂow demand. 7</description><a10:updated>2008-11-27T13:08:03+01:00</a10:updated></item><item><guid isPermaLink="true">http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=8</guid><link>http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=8</link><title>Danfoss Drives Page 8</title><description>Dedicated water features Auto tuning of the PI controllers With auto tuning of the PI controllers, the drive monitors how the system reacts on corrections made by the drive – and learns from it, so that precise and stable operation is achieved quickly. Gain factors for PI are continuously changed to compensate for changing characteristics of the loads. This applies to each PI controller in the 4-menu sets individually. Exact P and I settings at start-up will not be necessary – which lowers the commissioning costs. Pipe Fill Mode Enables controlled (closed loop) ﬁlling of pipes. Prevents water hammering, bursting water pipes or blowing off sprinkler heads. The new pipe fill mode is usable in both vertical and horizontal pipe systems. Useful in all applications where controlled pipe filling is demanded, such as irrigation systems, water supply systems, etc. End of Pump Curve detects breaks and leakage The feature detects breaks and leakage. End of curve triggers an alarm, shuts oﬀ the pump, or performs another programmed action whenever a pump is found running at full speed without creating the desired pressure – a situation that can arise when a pipe breaks or leakage occurs. Check Valve Ramp The Check Valve Ramp prevents water hammering as the pump stops and the check valve closes. The Check Valve Ramp slowly ramps down the pump speed around the value where the check valve ball is about to shut. 8</description><a10:updated>2008-11-27T13:08:03+01:00</a10:updated></item><item><guid isPermaLink="true">http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=9</guid><link>http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=9</link><title>Danfoss Drives Page 9</title><description>Dry Pump Protection lowers maintenance costs The VLT&amp;#174; AQUA Drive constantly evaluates the condition of the pump, based on internal frequency/power measurements. In case of a too low power consumption – indicating a no or low ﬂow situation – the VLT&amp;#174; AQUA Drive will stop. Sleep Mode Sleep Mode keeps pump wear and power consumption to an absolute minimum. In low ﬂow situations, the pump will boost the system pressure and then stop. Monitoring the pressure, the VLT&amp;#174; AQUA Drive will restart when the pressure falls below the required level. Flow compensation The flow compensation feature in VLT&amp;#174; AQUA Drive exploits the fact that flow resistance decreases with reduced flow. The pressure set point is accordingly reduced – which saves energy. Initial/Final Ramp The initial ramp provides fast acceleration of pumps to minimum speed, from where the normal ramp takes over. This prevents damage to the thrust bearings on the pump. The ﬁnal ramp decelerates pumps from min. speed to stop. Sensorless Pressure or Flow Control Sensorless pressure or ﬂow control is a patented VLT&amp;#174; feature that allows pump manufacturers to control the constant head (pressure) or ﬂow levels without the use of sensors. The cost and time of installing, cabling and maintaining pressure and ﬂow transducers are eliminated. Reliability is also boosted, as no additional components or connections can cause malfunction. Payback time indication One of the major reasons for applying a VLT&amp;#174; drive is the very short payback time due to energy savings. The VLT&amp;#174; AQUA drive comes with a unique feature which continuously shows the remaining payback time for the investment. Motor Alternation This built-in logic controls alternation between two pumps in duty/stand-by applications. Motion of the stand-by pump prevents sticking of the pump. An internal timer assures equal usage of the pumps. With an option card it is possible to control alternations between 8 pumps. 9</description><a10:updated>2008-11-27T13:08:03+01:00</a10:updated></item><item><guid isPermaLink="true">http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=10</guid><link>http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=10</link><title>Danfoss Drives Page 10</title><description>Athens Wastewater Treatment Plant, Greece VLT&amp;#174; drives up to 315 kW handle wastewater from a population of 5 million in Athens. VLT&amp;#174; operation saves approx. 25% energy. The Psyttalia Wastewater Treatment Plant treats daily 750.000 m3 of sewage and has a nominal daily capacity of 1.000.000 m3. 10</description><a10:updated>2008-11-27T13:08:03+01:00</a10:updated></item><item><guid isPermaLink="true">http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=11</guid><link>http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=11</link><title>Danfoss Drives Page 11</title><description>Proven AQUA experience Monterrey City, Mexico Agua y Drenaje de Monterrey in Mexico is installing Danfoss VLT&amp;#174; drives in wastewater treatment plants, boost pump stations and water wells for both residential and commercial areas in Monterrey – the largest industrial city in Mexico with 3.5 million people. Beneﬁts from VLT&amp;#174; operation of the pumps are energy savings of about 30% and also reduction of water leakage. Xi’An No.3 Waste Water treatment, China Danfoss provided VLT&amp;#174; AQUA drives and MCD soft starters for Xi’An No.3 Wastewater treatment plant. It is one of three bundles of a retroﬁt project to improve the environment in Xi’An City of Shanxi province, China. The treatment capacity is 100,000 tons of sewage and 50,000 tons of recycled water per day. Izmir Geothermal District Heating System, Turkey VLT&amp;#174; drives operate the deep well and supply pumps in Izmir geothermal district heating. Applying VLT&amp;#174; drives leads to a very low electricity cost. Vienna’s Main Sewage Treatment Plant, Austria At Vienna’s lowest point, where the Danube Canal meets the Danube, lies Vienna’s Main Sewage Treatment Plant. Here around 90% of Vienna’s wastewaters is puriﬁed. VLT&amp;#174; drives were chosen to operate the pumps that handle more than 500,000 cubic metres per day, which corresponds to a ﬂow of a mediumsize river. It takes about ﬁve hours for the wastewater to pass through the mechanical and biological puriﬁcation stages before it is puriﬁed and discharged into the Danube Canal. Perth Seawater Desalination Plant, Australia VLT&amp;#174; drives and soft starters were chosen to run pumps when The Water Corporation of Western Australia – one of Australia’s largest and most successful water service providers – invested $387 million Australian dollars in Perth Seawater Desalination Plant – the largest of its type in the Southern Hemisphere. The company provides water and wastewater services to the burgeoning city of Perth and hundreds of towns and communities spread over 2.5 million square kilometres. Changi Water Reclamation Plant, Singapore The Changi Water Reclamation plant is the cornerstone of the ﬁrst phase of the Singapore Deep Tunnel Sewerage System. The plant is to replace six existing water reclamation plants in the long term. Danfoss VLT&amp;#174; drives and AHF ﬁlters were supplied for chemical and carbon scrubbers for the odour control, sedimentation tanks, bio-reactors, sedimentation tanks and solids building. 11</description><a10:updated>2008-11-27T13:08:03+01:00</a10:updated></item><item><guid isPermaLink="true">http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=12</guid><link>http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=12</link><title>Danfoss Drives Page 12</title><description>AQUA users participated in developing the user interface Graphical display • International letters and signs • Showing bars and graphs • Easy overview • Possible to select 27 languages • iF awarded design Other benefits • Removable during operation • Up- and download functionality • IP 65 rating when mounted in a panel door • Up to 5 diﬀerent variables visible at a time Illumination • Important buttons are illuminated when active The VLT&amp;#174; AQUA Drive has an awardwinning Local Control Panel and a well structured menu system that ensures fast commissioning and trouble-free operation of the many powerful functions. Menu structure • Based on the well known matrix system in today’s VLT&amp;#174; drives • Easy shortcuts for the experienced user • Edit and operate in diﬀerent setups simultaneously Quick Menus • A Danfoss deﬁned Quick Menu • A Personal deﬁned Quick Menu • A Changes Made Menu lists the parameters unique for your application • A Function Setup menu provides quick and easy setup for speciﬁc applications • A Logging menu provides access to operation history Useful functions • Info (“on board manual”) • Cancel (“undo”) • Alarm log (quick access) Connection overview Power is connected to the terminals 91 (L1), 92 (L2) and 93 (L3) and the motor is connected to 96 (U), 97 (V) and 98 (W). Analog inputs can be connected to the 53 (V or mA), 54 (V or mA) terminals. These inputs can be set up for reference, feedback. There are 6 digital inputs to be connected to terminals 18, 19, 27, 29, 32, and 33. Two digital input/output terminals (27 and 29) can be set up as digital outputs to show an actual status or warning. The terminal 42 analog output can show process values such as 0 - Imax. 12</description><a10:updated>2008-11-27T13:08:03+01:00</a10:updated></item><item><guid isPermaLink="true">http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=13</guid><link>http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=13</link><title>Danfoss Drives Page 13</title><description>Specifications Mains supply (L1, L2, L3) Supply voltage Supply voltage Supply voltage Supply voltage Supply frequency True power factor (λ) Switching on input supply L1, L2, L3 Output data (U, V, W) Output voltage Switching on output Ramp times Closed loop 0 – 100% of supply voltage Unlimited 1 – 3600 sec 0 – 132 Hz 200 – 240 V &amp;#177;10% 380 – 480 V &amp;#177;10% 525 – 600 V &amp;#177;10% 525 – 690 V &amp;#177;10% 50/60 Hz ≥ 0.9 1-2 times/min. Application options A wide range of integrated water application options can be ﬁtted into the drive: • Real time clock with battery back-up • General purpose I/O option: 3 digital inputs, 2 digital outputs, 1 analog current output, 2 analog voltage inputs • Relay option/cascade controller option: 3 relay outputs • External 24 VDC supply option: 24 VDC external supply can be connected to supply control and option cards • Brake chopper option: Connected to an external brake resistor, the brake chopper limits the load on the intermediate circuit in case the motor acts as generator. • Extended cascade control of up to a total of 6 pumps • Advanced cascade control of up to a total of 8 pumps • Analogue sensor input option with up to 3 temperature sensor inputs VLT&amp;#174; AQUA Drive can provide 110% current for 1 minute. Higher overload rating is achieved by oversizing the drive. Digital inputs Programmable digital inputs Logic Voltage level Thermistor inputs *2 can be used as digital outputs 6* PNP or NPN 0 – 24 V 1 Power options Danfoss Drives oﬀers a wide range of external power options for use together with our drive in critical networks or applications: • Advanced Harmonic Filters: for applications where reducing harmonic distortion is critical Analog input Analog inputs Modes Voltage level Current level Pulse inputs Programmable pulse inputs Voltage level Pulse input accuracy Utilize some of the digital inputs Analog output Programmable analog outputs Current range at analog output Max. load (24 V) Relay outputs Programmable relay outputs (240 VAC, 2 A and 400 VAC, 2 A) Fieldbus communication Standard built in FC Protocol Modbus RTU Proﬁbus DeviceNet Ethernet 2 1 0/4 – 20 mA 130 mA 2 0-24 VDC (PNP positive logic) (0.1 – 110 kHz) 2 Voltage or current 0 – 10 V (scaleable) 0/4 – 20 mA (scaleable) • dU/dt ﬁlters: For providing motor isolation protection • Sine ﬁlters (LC ﬁlters): For noiseless motor and low dU/dt Complementary products • A broad range of soft starters • Decentral drive solutions PC software • MCT 10 – ideal for commissioning and servicing the drive including guided programming of cascade controller, real time clock, smart logic controller and preventive maintenance. The software is available for free on www.danfoss.com • VLT&amp;#174; Energy Box – comprehensive energy analysis tool, shows the drive payback time • MCT 31 – harmonics calculations tool Sales and Service Contacts worldwide Find your local expert team on www.danfoss.com/drives • 24/7 availability • Local service organisation is present in more than 100 countries – ready to support whenever and wherever you need, around the clock, 7 days a week. Optional Temperature Ambient temperature up to 55˚ C 13</description><a10:updated>2008-11-27T13:08:03+01:00</a10:updated></item><item><guid isPermaLink="true">http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=14</guid><link>http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=14</link><title>Danfoss Drives Page 14</title><description>Current, power and enclosure ratings 200 – 240 V IP 66 IP 20 IP 55 IP 21 Amp. FC 202 kW Amp. PK25 0.25 PK37 PK55 PK75 P1K1 P1K5 P2K2 P3K0 P3K7 P4K0 P5K5 P7K5 P11K P15K P18K P22K P30K P37K P45K P55K P75K P90K P110 P132 P160 P200 P250 P315 P355 P400 P450 P500 P560 P630 P710 P800 P900 0.37 0.55 0.75 1.1 1.5 2.2 3 3.7 4.0 5.5 7.5 11 15 18 22 30 37 45 55 75 90 110 132 160 200 250 315 355 400 450 500 560 630 710 800 900 1720 1530 F2/ F4 880 990 1120 1260 1460 780 F1/F3 890 1050 1160 1380 F2/ F4 F1/F3 24.2 30.8 B3 B1 B1 B1 46.2 59.4 74.8 88 115 143 170 B4 C3 B2 B2 B2 C1 C1 C1 1.8 2.4 3.5 4.6 6.6 7.5 10.6 12.5 16.7 A3 A3 A2 A2 A5 A5 1.3 1.8 2.4 3 4.1 5.6 7.2 10 13 16 24 32 37.5 44 61 73 90 106 147 212 1.2 1.6 2.1 2.7 3.4 4.8 6.3 8.2 11 14.5 21 27 34 40 52 65 80 105 130 160 212 260 315 395 480 600 658 745 800 190 240 302 361 443 540 590 678 730 E2 E1 E1 D4 D2 D2 D3 C3 C1 C1 C1 C2 C2 B4 B2 B2 B2 B3 B1 B1 B1 A2 A2 A3 A3 A5 A5 A2 A2 A5 A5 1.8 2.6 2.9 4.1 5.2 6.4 9.5 11.5 18 23 28 36 43 54 65 87 105 137 1.7 2.4 2.7 3.9 4.9 6.1 9 11 18 22 27 34 41 52 62 83 83 131 C3 C1 C1 C1 C4 C2 C2 C2 56 76 90 113 137 162 201 253 303 360 418 470 523 596 630 763 889 988 54 73 86 108 D3 D1 D1 131 155 192 242 290 D4 D2 D2 344 400 D4 D2 D2 450 500 570 630 F1/F3 F2/F4 F3 2282 607 850 945 F2/F4 F1/F3 730 E2 E1 E1 B4 B2 B2 B2 B3 B1 B1 B1 A2 A2 A3 A3 A5 A5 A2 A2 A5 A5 380 – 480 V IP 00 IP 66 IP 54 IP 20 IP 55 IP 21 Amp. &amp;lt;440 V &amp;gt;440 V &amp;lt;400 V &amp;gt;400 V 525 – 600 V IP 66 IP 20 IP 55 IP 21 Amp. &amp;lt;550 V &amp;gt;550 V 525 – 690 V IP 00 550 V 690 V IP 54 IP 21 Amp. C4 C2 C2 C2 C4 C2 D1 D1 P1M0 1000 P1M2 1200 1108 1060 1317 1260 F3 is a F1 frame with options cabinet; F4 is a F2 frame with options cabinet IP 00/Chassis IP 20/Chassis IP 21/NEMA Type 1 With upgrade kit IP 54/NEMA Type 12 IP 55/NEMA Type 12 IP 66/NEMA Type 4X Dimensions [mm] A1 H W D H+ W+ 200 75 90 205 308 94 372 134 A2 268 130 200 A3 A5 420 B1 481 242 261 B2 651 B3 350 165 248 490 170 B4 460 230 242 675 255 C1 681 308 310 C2 770 370 C3 490 306 335 760 330 955 395 C4 370 D1 420 380 D2 D3 D4 E1 600 494 E2 F1 F2 F4 600 1209 1589 1046 1327 2000 1547 408 375 498 2204 606 585 1400 1800 2000 2400 H+ and W+ is the height and width of IP 20 drives with IP 21/NEMA 1 upgrade kit 14</description><a10:updated>2008-11-27T13:08:03+01:00</a10:updated></item><item><guid isPermaLink="true">http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=15</guid><link>http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=15</link><title>Danfoss Drives Page 15</title><description>Choose conﬁgurations freely [1] FC 202 – [2] – [3] – [4] – [5] – [6] – [7] – [8] – [9] [10] [11] [12] [13] – [14] – [15] – [16] [17] – XX – [18] – X – X – SXX X – X – [2] Power Size See ratings data page14 [3] AC Line Voltage T2 3 x 220/240 VAC T4 3 x 380/480 VAC T6 T7 3 x 525/600 VAC 3 x 525/690 VAC [5] RFI Filter, Terminal &amp;amp; Monitoring Options D frames: H2 RFI ﬁlter, Class A2 (standard) H4 H6 RFI ﬁlter, Class A1 Maritime use RFI ﬁlter (consult Danfoss for applications requiring maritime certiﬁcation) [9] Mains Input X No option 7* A* D 3* 5* Fuses Fuses &amp;amp; load sharing terminals Load sharing terminals Mains disconnect &amp;amp; fuses Mains disconnect, fuses &amp;amp; loadsharing terminals [4] Enclosure D1 frames P110 or larger E21 IP21/NEMA 1 E54 E2M IP54/NEMA 12 IP21/NEMA 1 with mains shield E frames: H2 RFI ﬁlter, Class A2 (standard) H6 Maritime use RFI ﬁlter (consult Danfoss for applications requiring maritime certiﬁcation) *Not available in D frames with Class A1 RFI ﬁlter (525-690 VAC only) or maritime RFI ﬁlter [12] LCP Language X The AQUA Drive LCP has all languages as standard E5M IP54/NEMA 12 with mains shield D1 frames P90K size or smaller E2D IP21/NEMA 1 E5D E2M IP54/NEMA 12 IP21/NEMA 1 with mains shield 380-480 V only (T4 in position [3]): H4 RFI ﬁlter, Class A1 [6] Braking &amp;amp; Safety D &amp;amp; E frames: X No brake IGBT B T U Brake IGBT mounted Safe Stop (FC 102/202 only; std. on 302) Brake IGBT plus Safe Stop (FC 102/202 only; safe stop std. on 302) Consult factory for other language options [13] Fieldbus AX No ﬁeldbus option A0 A4 AN MCA 101 Proﬁbus DP V1 MCA 104 DeviceNet MCA 121 Ethernet I/P E5M IP54/NEMA 12 with mains shield D2 frames: E21 IP21/NEMA 1 E54 E2M IP54/NEMA 12 IP21/NEMA 1 with mains shield E frames: R Regeneration terminals [7] Local Control Panel D &amp;amp; E frames: N Numeric LCP installed G Graphic LCP installed D frames: IP00/Chassis or IP21/NEMA1 only (E21, E2M, E2D, E00, C00, E0D, C0D in position [4]): X Blank faceplate, no LCP installed [14] Application BX No application option BK BR BU BP B0 BY MCB 101 general purpose I/O MCB 102 encoder input MCB 103 resolver input MCB 105 relay expansion MCB 109 analogue I/O &amp;amp; real-time clock backup MCO 101 extended cascade control E5M IP54/NEMA 12 with mains shield D3 frames P110 size or larger E00 IP00/Chassis C00 IP00/Chassis w/stainless steel back channel D3 frames P90K size or smaller E0D IP00/Chassis C0D IP00/Chassis w/stainless steel back channel [15] Motion Control C5 MCO 102 advanced cascade control D4 frames: E00 IP00/Chassis C00 IP00/Chassis w/stainless steel back channel E1 frames: E21 IP21/NEMA 1 E54 E2M IP54/NEMA 12 IP21/NEMA 1 with mains shield [8] Conformal Coating D &amp;amp; E frames: C Conformal coating on all PCBs D frames: 380-480 only (T4 in position [3]): X No conformal coating [16] Extended Relay X No option [18] Control Power Backup Input DX No DC input installed D0 MCB 107 24 VDC backup input E5M IP54/NEMA 12 with mains shield E2 frames: E00 IP00/Chassis C00 IP00/Chassis w/ stainless steel back channel F1 E1 D2 An overview showing the many ways to conﬁgure a VLT&amp;#174; AQUA Drive Select the options required for your application to determine the type code for your drive. The factory then uses this type code to build the drive to your exact speciﬁcations. You can conﬁgure online at www.danfoss.com/drives – choose “Online Conﬁgurator” – or contact your local Danfoss Drives oﬃce. D1 C4 A2 A3 A4 A5 B1 B2 C1 C2 B4 C3 B3 15</description><a10:updated>2008-11-27T13:08:03+01:00</a10:updated></item><item><guid isPermaLink="true">http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=16</guid><link>http://nozebra.ipapercms.dk/Danfoss/DD/Global/Products/FC/VLTAQUADrive/ProductBrochure/?Page=16</link><title>Danfoss Drives Page 16</title><description>What VLT&amp;#174; is all about Danfoss Drives is the world leader among dedicated drives providers – and still gaining market share. Dedicated to drives Dedication has been a key word since 1968, when Danfoss introduced the world’s ﬁrst mass produced variable speed drive for AC motors – and named it VLT&amp;#174;. Two thousand employees develop, manufacture, sell and service drives and softstarters in more than one hundred countries, focused only on drives and soft starters. Intelligent and innovative Developers at Danfoss Drives have fully adopted modular principles in development as well as design, production and conﬁguration. Tomorrow’s features are developed in parallel using dedicated technology platforms. This allows the development of all elements to take place in parallel, at the same time reducing time to market and ensuring that customers always enjoy the beneﬁts of the latest features. Rely on the experts We take responsibility for every element of our products. The fact that we develop and produce our own features, hardware, software, power modules, printed circuit boards, and accessories is your guarantee of reliable products. Local backup – globally VLT&amp;#174; motor controllers are operating in applications all over the world and Danfoss Drives’ experts located in more than 100 countries are ready to support our customers with application advice and service wherever they may be. Danfoss Drives experts don’t stop until the customer’s drive challenges are solved. Environmentally responsible VLT&amp;#174; products are manufactured with respect for the safety and well-being of people and the environment. All activities are planned and performed taking into account the individual employee, the work environment and the external environment. Production takes place with a minimum of noise, smoke or other pollution and environmentally safe disposal of the products is prepared. UN Global Compact Danfoss has signed the UN Global Compact on social and environmental responsibility and our companies act responsibly towards local societies. EU Directives All factories are certiﬁed according to ISO 14001 standard. All products fulﬁl the EU Directives for General Product Safety and the Machinery directive. Danfoss Drives is, in all product series, implementing the EU Directive concerning Hazardous Substances in Electrical and Electrical Equipment (RoHS) and is designing all new product series according to the EU Directive on Waste Electrical and Electronic Equipment (WEEE). Impact on energy savings One year’s energy savings from the annual production of VLT&amp;#174; drives will save the energy equivalent to the energy production from a power plant. Better process control at the same time improves product quality and reduces waste and wear on equipment. Danfoss Drives, Ulsnaes 1, DK-6300 Graasten, Denmark, Tel. +45 74 88 22 22, Fax +45 74 65 25 80, www.danfoss.com/drives • E-mail: info@danfoss.com DKDD.PB.14.B1.02 VLT&amp;#174; is a trademark of Danfoss A/S Produced by DD-SMCC 2008.07</description><a10:updated>2008-11-27T13:08:03+01:00</a10:updated></item></channel></rss>